This allows for output identifiers and to be used in the `workspace
<workspace> output <outputs...>` command. Previously, only output names
would be allowed. If an output identifier was given, it would never match
an output. This also allows for the wildcard character (`*`) to be
specified, which can be used to generate a list of workspace names that
should be used when generating new workspaces
Enables titling views to be dragged by the titlebar. This is in addition
to using the modifier and dragging them from anywhere on the container
surface. Floating views already allow this behavior.
My previous attempt was not quite right. Changing the focus stack on a
non-visible workspace should only be blocked if the focus would be set
to the workspace itself
Default output configs were generated on reload to reset an output to
its default settings. The idea was that anything that was removed from
the config or changed at runtime and not in the config should be reset
on reload. Originally, they were created using the output name. Recently,
they were changed to use the output identifier. It turns out that there
are issues of shadowing with that solution as well. This should fix
those issues.
Instead of generating the default output configs on reload and storing
them in the output config list to merge on top of, they are now only
generated when retrieving the output config for an output during a
reload. This means that the default output configs are never stored
anywhere and just used as a base to merge unaltered user configs on top
of during a reload.
Starting with a blank output config, merges get applied in the following
order:
1. Default output config (only during a reload)
2. Wildcard config (only if neither output name or output identifier
exist)
3. Output name config
4. Output identifier config
This patch moves view_execute_criteria(view) below the fullscreen code.
Previously, if a view requested to be started in fullscreen, this was
done after execution of criteria and hence it was impossible to disable
fullscreen via criteria.
Fixes#3285
Changing the focus stack when destroying a container's node on a
non-visible workspace (on an non-focused output) incorrectly causes
the non-visible workspace to become visible. If the workspace is empty,
it will not be destroyed since it is now visible. Additionally since
there was no workspace::focus event, swaybar still shows the previous
workspace as focus-inactive. It also makes no sense to change visible
workspaces due to a container on a non-visible workspace being
destroyed.
Since the focus will either be set when switching to the non-visible
workspace or the workspace will be destroyed due to being empty, there
is no need to change the focus stack when destroying a container on a
non-visible workspace.
Determine the container/workspace a command is run on, each time when a
command of the command list will be run.
Previously the container/workspace was determined only once at the
beginning of command list execution, which led to wrong behaviour
because commands wouldn't take into account when a previous command
changed the focused container.
When generating default output configs to reset the outputs to their
default settings on reload, the output name was being used.
Additionally when determining the output config to apply, if there was
an output config with the output name, that was being used without
checking for an identifier config. This caused sway to completely ignore
the users specified output config.
To fix this issue, the following changes have been made:
1. Default output configs as created for the identifier now instead of
name. This actually makes more sense anyway since you could hotplug
multiple different outputs to the same port.
2. In get_output_config, which is only used to determine which output
config to apply, output configs for both the name and identifier are
queried. If both are found, a new output config is generated with the
identifier config merged on top of the name config. If just one is found,
a copy of that config is returned. This change also requires that the
result from get_output_config be freed after use to prevent memory
leaks, which required some minor changes to logic in
apply_output_config_to_outputs.
If a scratchpad container is hidden, it is still focusable using
criteria and should be shown. This fixes a segfault when attempting to
rebase the cursor since previously the scratchpad container would not be
on any output.
Changes the error result from CMD_INVALID to CMD_FAILURE, since
CMD_INVALID indicates an unknown command or parser error and neither
occurs where CMD_INVALID was used.
Since the output config is no longer applied before creating the default
workspace, the layout for default workspaces on an output may not be
correct. Due to the ordering of calls in output_enable being changed in
several bug fix PRs, this just fixes the layout after the call to
apply_output_config.
When adding a container to the scratchpad, it was possible for focus to
be removed from the seat. This occurred when a single child was moved
from it's parent to the scratchpad due to the focus_inactive for the
parent being NULL. If the focus_inactive for the parent is NULL, the
focus_inactive for the workspace should be focused.
Adds the bar subcommand `gaps <amount>|<horizontal> <vertical>|<top>
<right> <bottom> <left>` to set gaps for swaybar. Due to restrictions on
margins for a layer_surface, only the sides that are anchored to an edge
of the screen can have gaps. Since there is support for per-side outer
gaps for workspaces, those should be able to be used instead for the
last side.
In `i3 4.16`, `i3-msg` can be used with the message type `subscribe`
and has the ability to monitor for responses until killed. This adds
support for both to swaymsg.
If the JSON array of event types is malformed or contains an invalid
event, sway will send a response with `success` set to `false`. If
swaymsg sees this, it will not display the failure and exit.
If the `subscribe` event is successful, swaymsg will wait for the first
response and display that instead of the success message. If
`-m/--monitor` is given, swaymsg will continue monitor for responses
until killed or a malformed response is received.
For the `subscribe` event, the responses will always be printed as JSON.
If `-r/--raw` is given, the JSON will not be pretty printed, which may
be preferred when monitoring due to there being multiple responses.
Example: `swaymsg -t SUBSCRIBE -m "['window']"`
Adds the function `config_add_swaynag_warning(char *fmt, ...)` so that
handlers can add warnings to the swaynag config log in a uniform way.
The formatting is identical to errors and include the line number, line,
and config path.
This also alters the background file access warning to use the function
and introduces a warning for duplicate bindings.
moving a container to a non-empty workspace will find a container to move
to in the destination workspace and call container_move_to_container,
which must not just skip floating containers
Like with cmd_bindsym and cmd_bindcode, the quotes should not be
stripped for cmd_mode. cmd_mode performs its own stripping for the mode
name and the only valid subcommands are cmd_bindsym and cmd_bindcode.
This matches i3's behavior of returning a list of results that contain
the result of each command that was executed. Additionally, the
`parse_error` attribute has been added to the IPC JSON reply.
Damage subsurfaces when they are destroyed. Since subsurfaces don't have an
unmap event we need to do that on destroy.
We also don't want to keep a sway_view_child when the wlr_subsurface has been
destroyed.
Fixes https://github.com/swaywm/sway/issues/3197
This patch allows IPC clients to receive window::move events
when containers are moved to scratchpad or when hidden containers
are shown via "scratchpad show" command.
This adds support for `i3 4.16`'s ability to set the title alignment.
The command is `title_align left|center|right`.
When the title is on the right, marks are moved to the left. Otherwise,
they are on the right.
This commit fixes two bugs.
First, commit [1] has inverted the condition when we escape pango markup. We
need to escape client-provided strings when markup is enabled.
Second, parse_title_format has a shortcut when title_format is set to `%title`,
and escape_pango_markup wasn't used anymore there.
Fixes https://github.com/swaywm/sway/issues/3181
[1]: caee2dff03
The support for pango_markup was broken in title_format because the
formated title was escaped. I think only the payload should be escaped.
This commit fixes 789a877b37
This renames/moves the following properties:
* sway_view.{x,y,width,height} ->
sway_container.content_{x,y,width,height}
* This is required to support placeholder containers as they don't
have a view.
* sway_container_state.view_{x,y,width,height} ->
sway_container_state.content_{x,y,width,height}
* To remain consistent with the above.
* sway_container_state.con_{x,y,width,height} ->
sway_container_state.{x,y,width,height}
* The con prefix was there to give it contrast from the view
properties, and is no longer useful.
The function container_set_geometry_from_floating_view has also been
renamed to container_set_geometry_from_content.
In the conversion to `parse_boolean` for `cmd_ws_auto_back_and_forth`,
the `negation` was never removed causing the setting to be the opposite
of what it should be.
`i3 4.16` allows users to list multiple outputs for a workspace and the
first available will be used. The syntax is as follows:
`workspace <workspace> output <outputs...>`
Additionally when the workspace is created, the outputs get added to the
output priority list in the order specified. This ensures that if a higher
output gets connected, the workspace will move to the higher output. This
works the same way as if the user had a workspace on an output, disconnected
the output, and then later reconnected the output.
Currently, variables cannot contain commands and cannot span more than
one argument. This is due to variable replacement happening after
determining the handler and after splitting the config line into
arguments.
This changes the process to:
0. Check for empty lines and block boundaries
1. Split the arguments as before
2. Verify that the first argument is not a variable. If needed the
following occurs
a. Perform variable replacement on just the first argument
b. Join the arguments back together then split the arguments again. This is needed when the variable
contains the command and arguments for the command.
3. Determine the handler
4. If the handler is cmd_set, escape the variable name so that it does
not get replaced
5. Join the arguments back together, do variable replacement on the full
command, and split the arguments again
6. Perform any needed quote stripping or unescaping on arguments
7. Run the command handler
This allows for config snippets such as:
```
set $super bindsym Mod4
$super+a exec some-command
```
and
```
set $bg bg #ffffff solid_color
output * $bg
```
This implements the following syntaxes from `i3 4.16`:
* `resize set [width] <width> [px|ppt]`
* `resize set height <height> [px|ppt]`
* `resize set [width] <width> [px|ppt] [height] <height> [px|ppt]`
Additionally, a bug was fixed that caused setting the height of a tiled
container to change the width instead due to a typo.
This introduces the following command extensions from `i3-gaps`:
* `gaps horizontal|vertical|top|right|bottom|left <amount>`
* `gaps horizontal|vertical|top|right|bottom|left all|current
set|plus|minus <amount>`
* `workspace <ws> gaps horizontal|vertical|top|right|bottom|left
<amount>`
`inner` and `outer` are also still available as options for all three
of the above commands. `outer` now acts as a shorthand to set/alter
all sides.
Additionally, this fixes two bugs with the prevention of invalid gap
configurations for workspace configs:
1. If outer gaps were not set and inner gaps were, the outer gaps
would be snapped to the negation of the inner gaps due to `INT_MIN`
being less than the negation. This took precedence over the default
outer gaps.
2. Similarly, if inner gaps were not set and outer gaps were, inner
gaps would be set to zero, which would take precedence over the
default inner gaps.
Fixing both of the above items also requires checking the gaps again
when creating a workspace since the default outer gaps can be smaller
than the negation of the workspace specific inner gaps.
This commit enhances the output transform
command with options for a relative transform,
i.e. the provided transform will be applied as
an offset to the current transform. Append
`clockwise` to rotate clockwise from the current
rotation, or `anticlockwise` to rotate in the
opposite direction.
For example, if the output LVDS-1 is rotated
90 degrees clockwise, the command
`output LVDS-1 transform 90 clockwise`
will rotate the display to 180 degrees.
All transform options are supported,
including flipped transforms.
Relative transforms can only be applied to
a single output and cannot be used with
a wildcard (*) output specifier.