If a scratchpad container is hidden, it is still focusable using
criteria and should be shown. This fixes a segfault when attempting to
rebase the cursor since previously the scratchpad container would not be
on any output.
Changes the error result from CMD_INVALID to CMD_FAILURE, since
CMD_INVALID indicates an unknown command or parser error and neither
occurs where CMD_INVALID was used.
Since the output config is no longer applied before creating the default
workspace, the layout for default workspaces on an output may not be
correct. Due to the ordering of calls in output_enable being changed in
several bug fix PRs, this just fixes the layout after the call to
apply_output_config.
When adding a container to the scratchpad, it was possible for focus to
be removed from the seat. This occurred when a single child was moved
from it's parent to the scratchpad due to the focus_inactive for the
parent being NULL. If the focus_inactive for the parent is NULL, the
focus_inactive for the workspace should be focused.
Adds the bar subcommand `gaps <amount>|<horizontal> <vertical>|<top>
<right> <bottom> <left>` to set gaps for swaybar. Due to restrictions on
margins for a layer_surface, only the sides that are anchored to an edge
of the screen can have gaps. Since there is support for per-side outer
gaps for workspaces, those should be able to be used instead for the
last side.
In `i3 4.16`, `i3-msg` can be used with the message type `subscribe`
and has the ability to monitor for responses until killed. This adds
support for both to swaymsg.
If the JSON array of event types is malformed or contains an invalid
event, sway will send a response with `success` set to `false`. If
swaymsg sees this, it will not display the failure and exit.
If the `subscribe` event is successful, swaymsg will wait for the first
response and display that instead of the success message. If
`-m/--monitor` is given, swaymsg will continue monitor for responses
until killed or a malformed response is received.
For the `subscribe` event, the responses will always be printed as JSON.
If `-r/--raw` is given, the JSON will not be pretty printed, which may
be preferred when monitoring due to there being multiple responses.
Example: `swaymsg -t SUBSCRIBE -m "['window']"`
Adds the function `config_add_swaynag_warning(char *fmt, ...)` so that
handlers can add warnings to the swaynag config log in a uniform way.
The formatting is identical to errors and include the line number, line,
and config path.
This also alters the background file access warning to use the function
and introduces a warning for duplicate bindings.
moving a container to a non-empty workspace will find a container to move
to in the destination workspace and call container_move_to_container,
which must not just skip floating containers
Like with cmd_bindsym and cmd_bindcode, the quotes should not be
stripped for cmd_mode. cmd_mode performs its own stripping for the mode
name and the only valid subcommands are cmd_bindsym and cmd_bindcode.
This matches i3's behavior of returning a list of results that contain
the result of each command that was executed. Additionally, the
`parse_error` attribute has been added to the IPC JSON reply.
Damage subsurfaces when they are destroyed. Since subsurfaces don't have an
unmap event we need to do that on destroy.
We also don't want to keep a sway_view_child when the wlr_subsurface has been
destroyed.
Fixes https://github.com/swaywm/sway/issues/3197
This patch allows IPC clients to receive window::move events
when containers are moved to scratchpad or when hidden containers
are shown via "scratchpad show" command.
This adds support for `i3 4.16`'s ability to set the title alignment.
The command is `title_align left|center|right`.
When the title is on the right, marks are moved to the left. Otherwise,
they are on the right.
This commit fixes two bugs.
First, commit [1] has inverted the condition when we escape pango markup. We
need to escape client-provided strings when markup is enabled.
Second, parse_title_format has a shortcut when title_format is set to `%title`,
and escape_pango_markup wasn't used anymore there.
Fixes https://github.com/swaywm/sway/issues/3181
[1]: caee2dff03
The support for pango_markup was broken in title_format because the
formated title was escaped. I think only the payload should be escaped.
This commit fixes 789a877b37
This renames/moves the following properties:
* sway_view.{x,y,width,height} ->
sway_container.content_{x,y,width,height}
* This is required to support placeholder containers as they don't
have a view.
* sway_container_state.view_{x,y,width,height} ->
sway_container_state.content_{x,y,width,height}
* To remain consistent with the above.
* sway_container_state.con_{x,y,width,height} ->
sway_container_state.{x,y,width,height}
* The con prefix was there to give it contrast from the view
properties, and is no longer useful.
The function container_set_geometry_from_floating_view has also been
renamed to container_set_geometry_from_content.
In the conversion to `parse_boolean` for `cmd_ws_auto_back_and_forth`,
the `negation` was never removed causing the setting to be the opposite
of what it should be.
`i3 4.16` allows users to list multiple outputs for a workspace and the
first available will be used. The syntax is as follows:
`workspace <workspace> output <outputs...>`
Additionally when the workspace is created, the outputs get added to the
output priority list in the order specified. This ensures that if a higher
output gets connected, the workspace will move to the higher output. This
works the same way as if the user had a workspace on an output, disconnected
the output, and then later reconnected the output.
Currently, variables cannot contain commands and cannot span more than
one argument. This is due to variable replacement happening after
determining the handler and after splitting the config line into
arguments.
This changes the process to:
0. Check for empty lines and block boundaries
1. Split the arguments as before
2. Verify that the first argument is not a variable. If needed the
following occurs
a. Perform variable replacement on just the first argument
b. Join the arguments back together then split the arguments again. This is needed when the variable
contains the command and arguments for the command.
3. Determine the handler
4. If the handler is cmd_set, escape the variable name so that it does
not get replaced
5. Join the arguments back together, do variable replacement on the full
command, and split the arguments again
6. Perform any needed quote stripping or unescaping on arguments
7. Run the command handler
This allows for config snippets such as:
```
set $super bindsym Mod4
$super+a exec some-command
```
and
```
set $bg bg #ffffff solid_color
output * $bg
```
This implements the following syntaxes from `i3 4.16`:
* `resize set [width] <width> [px|ppt]`
* `resize set height <height> [px|ppt]`
* `resize set [width] <width> [px|ppt] [height] <height> [px|ppt]`
Additionally, a bug was fixed that caused setting the height of a tiled
container to change the width instead due to a typo.
This introduces the following command extensions from `i3-gaps`:
* `gaps horizontal|vertical|top|right|bottom|left <amount>`
* `gaps horizontal|vertical|top|right|bottom|left all|current
set|plus|minus <amount>`
* `workspace <ws> gaps horizontal|vertical|top|right|bottom|left
<amount>`
`inner` and `outer` are also still available as options for all three
of the above commands. `outer` now acts as a shorthand to set/alter
all sides.
Additionally, this fixes two bugs with the prevention of invalid gap
configurations for workspace configs:
1. If outer gaps were not set and inner gaps were, the outer gaps
would be snapped to the negation of the inner gaps due to `INT_MIN`
being less than the negation. This took precedence over the default
outer gaps.
2. Similarly, if inner gaps were not set and outer gaps were, inner
gaps would be set to zero, which would take precedence over the
default inner gaps.
Fixing both of the above items also requires checking the gaps again
when creating a workspace since the default outer gaps can be smaller
than the negation of the workspace specific inner gaps.
This commit enhances the output transform
command with options for a relative transform,
i.e. the provided transform will be applied as
an offset to the current transform. Append
`clockwise` to rotate clockwise from the current
rotation, or `anticlockwise` to rotate in the
opposite direction.
For example, if the output LVDS-1 is rotated
90 degrees clockwise, the command
`output LVDS-1 transform 90 clockwise`
will rotate the display to 180 degrees.
All transform options are supported,
including flipped transforms.
Relative transforms can only be applied to
a single output and cannot be used with
a wildcard (*) output specifier.
The exec_always command was executed twice, since it was not checking for the
config->validating variable.
Fix this by defering the command if the configuration is validating.
Fixes#3072
It appears that the focus code that handles `focus_wrapping yes` was
removed during the conversion to type safety. This re-implements the
focus code for when `focus_wrapping` is set to `yes` (default). Neither
the `no` or `force` options appear to be effected and should be working.