You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
78 lines
2.1 KiB
78 lines
2.1 KiB
#include "sway/commands.h"
|
|
#include "sway/config.h"
|
|
#include "sway/output.h"
|
|
#include "list.h"
|
|
#include "log.h"
|
|
|
|
// must be in order for the bsearch
|
|
static struct cmd_handler output_handlers[] = {
|
|
{ "background", output_cmd_background },
|
|
{ "bg", output_cmd_background },
|
|
{ "disable", output_cmd_disable },
|
|
{ "dpms", output_cmd_dpms },
|
|
{ "enable", output_cmd_enable },
|
|
{ "mode", output_cmd_mode },
|
|
{ "pos", output_cmd_position },
|
|
{ "position", output_cmd_position },
|
|
{ "res", output_cmd_mode },
|
|
{ "resolution", output_cmd_mode },
|
|
{ "scale", output_cmd_scale },
|
|
{ "transform", output_cmd_transform },
|
|
};
|
|
|
|
struct cmd_results *cmd_output(int argc, char **argv) {
|
|
struct cmd_results *error = checkarg(argc, "output", EXPECTED_AT_LEAST, 1);
|
|
if (error != NULL) {
|
|
return error;
|
|
}
|
|
|
|
struct output_config *output = new_output_config(argv[0]);
|
|
if (!output) {
|
|
sway_log(SWAY_ERROR, "Failed to allocate output config");
|
|
return NULL;
|
|
}
|
|
argc--; argv++;
|
|
|
|
config->handler_context.output_config = output;
|
|
|
|
while (argc > 0) {
|
|
config->handler_context.leftovers.argc = 0;
|
|
config->handler_context.leftovers.argv = NULL;
|
|
|
|
if (find_handler(*argv, output_handlers, sizeof(output_handlers))) {
|
|
error = config_subcommand(argv, argc, output_handlers,
|
|
sizeof(output_handlers));
|
|
} else {
|
|
error = cmd_results_new(CMD_INVALID,
|
|
"Invalid output subcommand: %s.", *argv);
|
|
}
|
|
|
|
if (error != NULL) {
|
|
goto fail;
|
|
}
|
|
|
|
argc = config->handler_context.leftovers.argc;
|
|
argv = config->handler_context.leftovers.argv;
|
|
}
|
|
|
|
config->handler_context.output_config = NULL;
|
|
config->handler_context.leftovers.argc = 0;
|
|
config->handler_context.leftovers.argv = NULL;
|
|
|
|
output = store_output_config(output);
|
|
|
|
// If reloading, the output configs will be applied after reading the
|
|
// entire config and before the deferred commands so that an auto generated
|
|
// workspace name is not given to re-enabled outputs.
|
|
if (!config->reloading) {
|
|
apply_output_config_to_outputs(output);
|
|
}
|
|
|
|
return cmd_results_new(CMD_SUCCESS, NULL);
|
|
|
|
fail:
|
|
config->handler_context.output_config = NULL;
|
|
free_output_config(output);
|
|
return error;
|
|
}
|