You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

87 lines
2.4 KiB

#include <strings.h>
#include "sway/commands.h"
#include "sway/config.h"
#include "sway/output.h"
#include "list.h"
#include "log.h"
// must be in order for the bsearch
static struct cmd_handler output_handlers[] = {
{ "background", output_cmd_background },
{ "bg", output_cmd_background },
{ "disable", output_cmd_disable },
{ "dpms", output_cmd_dpms },
{ "enable", output_cmd_enable },
{ "mode", output_cmd_mode },
{ "pos", output_cmd_position },
{ "position", output_cmd_position },
{ "res", output_cmd_mode },
{ "resolution", output_cmd_mode },
{ "scale", output_cmd_scale },
{ "subpixel", output_cmd_subpixel },
{ "transform", output_cmd_transform },
};
struct cmd_results *cmd_output(int argc, char **argv) {
struct cmd_results *error = checkarg(argc, "output", EXPECTED_AT_LEAST, 1);
if (error != NULL) {
return error;
}
// The NOOP-1 output is a dummy output used when there's no outputs
// connected. It should never be configured.
if (strcasecmp(argv[0], root->noop_output->wlr_output->name) == 0) {
return cmd_results_new(CMD_FAILURE,
"Refusing to configure the no op output");
}
struct output_config *output = new_output_config(argv[0]);
if (!output) {
sway_log(SWAY_ERROR, "Failed to allocate output config");
return NULL;
}
argc--; argv++;
config->handler_context.output_config = output;
while (argc > 0) {
config->handler_context.leftovers.argc = 0;
config->handler_context.leftovers.argv = NULL;
if (find_handler(*argv, output_handlers, sizeof(output_handlers))) {
error = config_subcommand(argv, argc, output_handlers,
sizeof(output_handlers));
} else {
error = cmd_results_new(CMD_INVALID,
"Invalid output subcommand: %s.", *argv);
}
if (error != NULL) {
goto fail;
}
argc = config->handler_context.leftovers.argc;
argv = config->handler_context.leftovers.argv;
}
config->handler_context.output_config = NULL;
config->handler_context.leftovers.argc = 0;
config->handler_context.leftovers.argv = NULL;
output = store_output_config(output);
// If reloading, the output configs will be applied after reading the
// entire config and before the deferred commands so that an auto generated
// workspace name is not given to re-enabled outputs.
if (!config->reloading) {
apply_output_config_to_outputs(output);
}
return cmd_results_new(CMD_SUCCESS, NULL);
fail:
config->handler_context.output_config = NULL;
free_output_config(output);
return error;
}